1-91
1 to 199
A communication or network addressing problem exists in your
network environment, so the MicroKernel requests never reach
their destination server address. Ensure that your client and
server network components are up to date and certified for your
network environment.
³ To adjust the Receive Packet Size:
1 Access the server properties in PCC (see To access configuration
settings in PCC for a local client in Advanced Operations Guide.
2 Click Communication Buffer Size in the properties tree.
3 Ensure that the Receive Packet Size value is appropriate for your
environment.
92: The transaction table is full
This status code is obsolete in MicroKernel versions 7.0 and later.
The application exceeded the maximum number of active
transactions. Use the configuration properties to specify a higher
value for the Number of Transactions configuration option.
93: The record lock types are incompatible
The application tried to mix single-record locks (+100/+200) and
multiple-record locks (+300/+400) in the same file at the same time.
You must release all locks of one type before you can execute a lock
of the other type.
94: The application encountered a permission error
The MicroKernel returns this status code in the following situations:
The application tried to open or create a file in a directory
without the proper privileges. The MicroKernel does not
override the network privileges assigned to users.
The designated server is in the server routing table, but your
particular client is not logged into that server.
The system data source name (DSN) on the server has an error
in the pathname to the data files.